GRP round rods are made with thermoset polyester resin reinforced with glass fibers. Surface adhesion is improved by a helicoidal groove produced without cutting the surface or any fibers and therefore there is no reduction in the mechanical characteristics in the axial direction. Reduction of such characteristics is typical for other similar products and is a result of cutting the reinforcing glass fibers. GRP rods are utilized mainly for the fabrication of cages or as nails or anchoring systems (active and passive).
Tests can be performed according to ACI 440, CNR DT203/206. Procedures for designing, executing and controlling structures in concrete reinforced with glass reinforced composite rods, and various other local codes. Please contact ATP Technical Department for specific codes and applications.
APPLICATIONS
- Reinforced Concrete in a Corrosive Environment
- Structures exposed to salt for melting ice: Bridge slabs, parking lots, railroad crossings, highway dividing barriers, salt storage stations.
- Structures exposed to sea salt: Buildings near the coast, aquaculture structures, seaport docks, immersed structures.
- Reinforced Concrete in Electromagnetic Environments
- Magnetic resonance chambers in hospitals
- Helicopter landing pads
- Airport structures and radar towers
- High-voltage electrical transformer platforms
- Electrical substations
PHYSICAL/MECHANICAL PROPERTIES-ROCKWORM RWBP
(POLYESTER MATRIX) AND RWBV (VINYL ESTER MATRIX)
Rebar
Diameter
(mm) |
Minimum Guaranteed
Tensile Strength |
Modulus of Elasticity |
GFRP (N/mm2) |
GFRP (N/mm2) |
14 |
675 |
40000 |
16 |
655 |
40000 |
18 |
630 |
40000 |
20 |
610 |
40000 |
22 |
585 |
40000 |
24 |
560 |
40000 |
28 |
525 |
40000 |
30 |
505 |
40000 |
32 |
480 |
40000 |
|
|
|
The values shown above are indicative and, in some way, cautionary
“Rockworm” rebar is in the phase of official laboratory testing following the recommendations of ACI440.3R-04 .